Designed to meet the challenges of the most demanding
environments, ATAboy2 delivers unparalleled availability and
performance in an ATA RAID device. With sustained thoughput
speeds of up to 170 MB/s per controller, ATAboy2 provides high
performance across all standard platforms and operating systems.
Quad SCSI or dual 2Gb fibre channel connectors (per controller)
enable easy and flexible implementation into a wide range of
environments. Ataboy2's unique combination of high performance
and enormous capacity provides exceptional value that enhances
all digital storage applications, such as live on-line data,
HDTV, digital film and video, nearline storage, security, audio,
disk-based backup (D2D) and disaster recovery.
Unsurpassed reliability
results from utilizing redundancy, advanced ATA disk
drives and the latest in RAID technology. The Nexsan
designed GUI interface, NexSCAN™, provides the latest in
centralized management and monitoring features for all
Nexsan subsystems. Tele-Guard™, Nexsan's phone home
manager, provides operator selectable parameters
monitoring all system conditions. Tele-Guard™ provides the
vehicle to notify single or multiple system operators of
any user defined, system triggered event. In addition to
supporting On-Line Hot-Swap for all active components, the
InfiniSAN ATAboy unique run-time diagnostics and error
handling software monitors automatic fail over initiation
for all active components. InfiniSAN ATAboy2 ATA
disk-based systems provide the maximum uptime operation
and data protected environment available today.

|
 |
Continual event
monitoring with active user notification. |
|
 |
Dynamic spare
pooling and dedicated spares; array
verification. |
|
 |
All major
components are hot swap supported |
|
 |
Tele-Guard™ -
Active/Dynamic phone home notification.
|
|
 |
Active array
status monitoring; adjustable stripe width;
automatic sector re-mapping. |
|
 |
Write-back data
cache memory bus, 800 Mbytes/sec bandwidth. |
|
 |
User-settable
priorities for dynamic array reconstruct,
verify, create and expand operations. |
|
 |
Centrally or
remotely managed dynamic storage pooling and
virtual volume allocations. |
|
 |
System security
password protected. |
|
|
 |
Serial port
access. |
|
 |
All system
settings are stored in non-volatile flash
memory in case of accidental power loss. |
|
 |
Graphic display
of enclosure layout including rack and tower
orientation. |
|
 |
Alarm status
displayed on the events page directly
translated from and associated with the
occurrence. |
|
 |
Arrays can be
configured for RAID levels 0, 4, 5 |
|
 |
Up to 16 LUNS per
SCSI controller, 32 LUNS per Fibre controller
|
|
 |
Auto rescan -
initiates automatic system scans for real-time
"Correct Status" reporting for all RAID arrays
and connected disk drives. |
|
 |
Parity Scrub /
Array Verify scheduling - User defined
automatic repair of all configured arrays. |
|
|

Veriture, Nexsan's
innovative virtualization application, offers the
latest advances in on-line configuration and
allows storage pools and virtual volumes to be
built dynamically from unique physical storage
devices.
Configure your
Fibre based SAN utilizing Veriture VSM or use the
latest IP network-based (iSCSI) SAN technology
with Veriture IP.
Advanced features
include:
Snap Shot, Bit level replication and Virtual Tape.
On-Line Capacity Expansion (OCE), Dynamic Spares
Allocation (DSA). Hot spare drives can be added
and deleted either as a pool or an array dedicated
spare.
Dynamic Array Expansion (DAE) and Dynamic
Partition Expansion (DPE)
Veriture applications
allow true on-line load balancing providing
multiple points of support for the management of
the virtualization application.
Tele-Guard is Nexsan
Technologies' phone home feature incorporated within the
InfiniSAN line of storage solutions. Utilizing NexScan™,
our WEB enabled GUI (Graphical User Interface), you can
access your system from any standard internet browser. In
addition, NexScan™ is platform independent and can be
accessed directly from a host computer or over a LAN or
WAN. No software patches required.
NexScan™ uses standard
html eliminating any need for special client software.
Tele-Guard™ monitors all system parameters and you can
select either single or multiple user alerts to be sent
via ' Plain English ' e-mails, Internet based SMS
notification or Tele-Guard's™ pager support.

 |
NexScan™ is our
embedded WEB enabled GUI ( Graphical User
Interface ). Platform independent. Access
your system from any standard internet
browser or from any host computer either
directly connected or via a LAN or WAN. No
software or patches required.
 |
Additional
access via the RS-232 serial port or
network interface to an ANSI terminal or
emulator. |
 |
SCSI ID,
maximum transfer rate, and termination
can be individually set for each Host
Port (InfiniSAN-2s only) |
 |
Event log
for all significant events stored on
disk. |
 |
SAF-TE and
SMART environmental monitoring support. |
 |
Single
click access to summary of all problems
and warnings. |
 |
DNS support
for symbolic addresses. |
 |
Array is
verified before being put into
production; automatic "parity scrub"
(array verify) is performed as a
background task every 24 hours
thereafter. |
 |
Build RAID
sets (and set RAID level and stripe
size), partition RAID sets into Volumes,
map Volumes to LUNs and Host Ports, and
manage Spares |
 |
Shows
status of disk drives, power supplies,
fans, RAID controller. Information
is automatically refreshed at a settable
interval. |
 |
For each
drive, complete Model Name, Capacity,
Serial Number, and Firmware Revision is
reported along with errors and retries,
if any. |
 |
Complete
hardware status page lists all
significant hardware conditions such as
voltages, temperature, battery mode,
cache settings, network settings, and
blower RPM |
 |
Alerts and
warnings sent out using SMTP email
alerts with problem summary, hyperlink
to the enclosure management page, plus
user-defined fields. |
 |
Supports
automatic IP address assignment via DHCP,
manually using IP Gleaning, over serial
port, or via web page. |
 |
Extra
security feature requires manual
confirmation of destructive media
operations. |
 |
Cache
management page allows configuration of
Cache as enabled or disabled, or
remotely settable via standard SCSI
commands |
 |
Battery-backed Real Time Clock/Calendar
is used to time stamp all major events |
 |
Configure
and monitor subsystem using any standard
web browser. |
|
|
|

|
Regulatory Approvals |
CE, UL,
CUL |
Three Years
Advance Replacement Warranty:
Nexsan Technologies storage systems are
warranted fully for three full years from
the date of shipment. Upon verification of
failure, replacement equipment will be
shipped out to our customers in advance of
receiving the defective subassembly. Return
material authorizations will accompany all
equipment shipped and can be issued either
by our 24-hour free phone support, fax,
email or via our Web site.
On
Location Pre-Exchange Program:
An industry first program for maximum
protection of critical storage devices, this
program provides customers with an on
location unit that features fully redundant
fail-over hardware including the chassis for
a nominal annual charge. This program
enables our customers to have in their rack
chassis a fully implemented system. Along
with our 24-hour free phone support,
customers can now be assured of rapid
resolution to any problem. Defective
components can then be advance replaced for
constant availability.
On Site
Warranty:
Nexsan offers World Wide On-Site support
seven days a week, twenty-four hours a day
with a next business day response. (Some
countries vary, check with your sales
representative for specific regional
details). A simple call to our European or
North American support offices and we will
assist in diagnosis and dispatch an on-site
technician as required. A call tracking
number will be issued for convenience to our
customers.
Telephone
Support:
Nexsan Technologies is fully staffed in
providing multiple regional Support centers
in North America, United Kingdom and Central
Europe. All of our regional support centers
staff Senior Field Application Engineers who
can provide phone or on-site support as
requested. Support can be also be reached
via email at
support@nexsan.com.
|
|
|
|