Product Overview
Nexsan's InfiniSAN line of disk-based Storage Solutions delivers the latest in form and function now. The InfiniSAN ATAboy series provides Enterprise-class features and functionality in a low profile, cost correct expandable package. Nexsan designed the InfiniSAN ATAboy2 for maximum flexibility and scalability. All of the ATAboy2's critical components, including the RAID controllers and host connections, are user-pluggable. This design provides reliable, redundant data protection while enabling users to maximize the return on their storage hardware investment by extending the capabilities of the ATAboy system with future upgrades for enhanced performance and functionality.

Unsurpassed Data Availability
Designed to meet the challenges of the most demanding environments, ATAboy2 delivers unparalleled availability and performance in an ATA RAID device. With sustained thoughput speeds of up to 170 MB/s per controller, ATAboy2 provides high performance across all standard platforms and operating systems. Quad SCSI or dual 2Gb fibre channel connectors (per controller) enable easy and flexible implementation into a wide range of environments. Ataboy2's unique combination of high performance and enormous capacity provides exceptional value that enhances all digital storage applications, such as live on-line data, HDTV, digital film and video, nearline storage, security, audio, disk-based backup (D2D) and disaster recovery.

 

Cost Correct Enterprise Class Reliability

Unsurpassed reliability results from utilizing redundancy, advanced ATA disk drives and the latest in RAID technology. The Nexsan designed GUI interface, NexSCAN™, provides the latest in centralized management and monitoring features for all Nexsan subsystems. Tele-Guard™, Nexsan's phone home manager, provides operator selectable parameters monitoring all system conditions. Tele-Guard™ provides the vehicle to notify single or multiple system operators of any user defined, system triggered event. In addition to supporting On-Line Hot-Swap for all active components, the InfiniSAN ATAboy unique run-time diagnostics and error handling software monitors automatic fail over initiation for all active components. InfiniSAN ATAboy2 ATA disk-based systems provide the maximum uptime operation and data protected environment available today.

Advanced Features

Continual event monitoring with active user notification.

Dynamic spare pooling and dedicated spares; array verification.

All major components are hot swap supported

Tele-Guard™ - Active/Dynamic phone home notification.

Active array status monitoring; adjustable stripe width; automatic sector re-mapping.

Write-back data cache memory bus, 800 Mbytes/sec bandwidth.

User-settable priorities for dynamic array reconstruct, verify, create and expand operations.

Centrally or remotely managed dynamic storage pooling and virtual volume allocations.

System security password protected.

Serial port access.

All system settings are stored in non-volatile flash memory in case of accidental power loss.

Graphic display of enclosure layout including rack and tower orientation.

Alarm status displayed on the events page directly translated from and associated with the occurrence.

Arrays can be configured for RAID levels 0, 4, 5

Up to 16 LUNS per SCSI controller, 32 LUNS per Fibre controller

Auto rescan - initiates automatic system scans for real-time "Correct Status" reporting for all RAID arrays and connected disk drives.

Parity Scrub / Array Verify scheduling - User defined automatic repair of all configured arrays.

Storage Virtualization
 
Veriture, Nexsan's innovative virtualization application, offers the latest advances in on-line configuration and allows storage pools and virtual volumes to be built dynamically from unique physical storage devices.

Configure your Fibre based SAN utilizing Veriture VSM or use the latest IP network-based (iSCSI) SAN technology with Veriture IP.

Advanced features include:

Snap Shot, Bit level replication and Virtual Tape.
On-Line Capacity Expansion (OCE), Dynamic Spares Allocation (DSA). Hot spare drives can be added and deleted either as a pool or an array dedicated spare.
Dynamic Array Expansion (DAE) and Dynamic Partition Expansion (DPE)
Veriture applications allow true on-line load balancing providing multiple points of support for the management of the virtualization application.
Technical Specifications
External Host Interface / Channels:
Ultra 160 SCSI SE/LVD / 1Gb and 2Gb Fibre Channel
Internal Device Interface / Channels:
Fourteen ATA/100 device channels
Data TransferRates SCSI: Up to 200MB/s with dual controller
Fibre: Up to 400MB/s, 170MB/s sustained per controller, 25,000 IOPS
Power Power
Current Voltage 25ºC cold start Dual PSU 4A @ 115 or 2A @ 230 Switchable 115/230 Optional Autoranging with Power Factor Correction
Frequency   47-63 Hz
Operating Temperature   0°C to 40°C (32°F to 104°F)
  Tower Rack Stacker
Height 19 in. 5.25 in. 8 in.
Width 8 in. 19 in. 19 in.
Depth 21in. 21in. 21in.
Weight (without disk drives) 53 lbs 46 lbs 53 lbs
Specifications subject to change without notice. Agency approvals are pending
TeleGuard - Phone Home
Tele-Guard is Nexsan Technologies' phone home feature incorporated within the InfiniSAN line of storage solutions. Utilizing NexScan™, our WEB enabled GUI (Graphical User Interface), you can access your system from any standard internet browser. In addition, NexScan™ is platform independent and can be accessed directly from a host computer or over a LAN or WAN. No software patches required.

NexScan™ uses standard html eliminating any need for special client software. Tele-Guard™ monitors all system parameters and you can select either single or multiple user alerts to be sent via ' Plain English ' e-mails, Internet based SMS notification or Tele-Guard's™ pager support.

Nexsan - GUI
Configuration And Management
NexScan™ is our embedded WEB enabled GUI ( Graphical User Interface ). Platform independent. Access your system from any standard internet browser or from any host computer either directly connected or via a LAN or WAN. No software or patches required.
Additional access via the RS-232 serial port or network interface to an ANSI terminal or emulator. SCSI ID, maximum transfer rate, and termination can be individually set for each Host Port (InfiniSAN-2s only)
Event log for all significant events stored on disk. SAF-TE and SMART environmental monitoring support.
Single click access to summary of all problems and warnings. DNS support for symbolic addresses.
Array is verified before being put into production; automatic "parity scrub" (array verify) is performed as a background task every 24 hours thereafter. Build RAID sets (and set RAID level and stripe size), partition RAID sets into Volumes, map Volumes to LUNs and Host Ports, and manage Spares
Shows status of disk drives, power supplies, fans, RAID controller. Information
is automatically refreshed at a settable interval.
For each drive, complete Model Name, Capacity, Serial Number, and Firmware Revision is reported along with errors and retries, if any.
Complete hardware status page lists all significant hardware conditions such as voltages, temperature, battery mode, cache settings, network settings, and blower RPM Alerts and warnings sent out using SMTP email alerts with problem summary, hyperlink to the enclosure management page, plus user-defined fields.
Supports automatic IP address assignment via DHCP, manually using IP Gleaning, over serial port, or via web page. Extra security feature requires manual confirmation of destructive media operations.
Cache management page allows configuration of Cache as enabled or disabled, or remotely settable via standard SCSI commands Battery-backed Real Time Clock/Calendar is used to time stamp all major events
Configure and monitor subsystem using any standard web browser.
Warrenty/Support/Services
Regulatory Approvals CE, UL, CUL
Three Years Advance Replacement Warranty:
Nexsan Technologies storage systems are warranted fully for three full years from the date of shipment. Upon verification of failure, replacement equipment will be shipped out to our customers in advance of receiving the defective subassembly. Return material authorizations will accompany all equipment shipped and can be issued either by our 24-hour free phone support, fax, email or via our Web site.

On Location Pre-Exchange Program:
An industry first program for maximum protection of critical storage devices, this program provides customers with an on location unit that features fully redundant fail-over hardware including the chassis for a nominal annual charge. This program enables our customers to have in their rack chassis a fully implemented system. Along with our 24-hour free phone support, customers can now be assured of rapid resolution to any problem. Defective components can then be advance replaced for constant availability.

On Site Warranty:
Nexsan offers World Wide On-Site support seven days a week, twenty-four hours a day with a next business day response. (Some countries vary, check with your sales representative for specific regional details). A simple call to our European or North American support offices and we will assist in diagnosis and dispatch an on-site technician as required. A call tracking number will be issued for convenience to our customers.

Telephone Support:
Nexsan Technologies is fully staffed in providing multiple regional Support centers in North America, United Kingdom and Central Europe. All of our regional support centers staff Senior Field Application Engineers who can provide phone or on-site support as requested. Support can be also be reached via email at support@nexsan.com.